Perfact products are provided through
various types of clinical trials.
various types of clinical trials.
Internal Hex Fixture : SST Type

SG Meditech conducts various clinical experiments to provide customers with the finest products. Shinsegi Meditech succes sfully presents 100% completed products
through continuous research in efforts to be recognized as a credible company.
Patient Information
- Age : 61
- Gender : old male
- Implant : 15, 16, 17, 27 SST implants

Fig1.
Implant placement combined socket lifting
Implant placement combined socket lifting

Fig2.
Initial panorama x-ray
Initial panorama x-ray

Fig3.
Sinus grafting performed by crestal approach on the #16,17 area
Sinus grafting performed by crestal approach on the #16,17 area

Fig4.
SG Implants were installed. Pictures of SST system #15,16 SFSR4111 . #17 SFSW511
SG Implants were installed. Pictures of SST system #15,16 SFSR4111 . #17 SFSW511

Fig5.
Primary stability checked with Torque Wrench
Primary stability checked with Torque Wrench

Fig6.
The picture taken after the SST implants placed
The picture taken after the SST implants placed

Fig7.
Healing aboutments were inserted
Healing aboutments were inserted

Fig8. #14, 15, 16 SST implants installed & Healing aboutments were insertered.
#27 implant was inserted combined socket lifting

Fig9.
Healing sequences of sinus area
Healing sequences of sinus area

Fig10.
Impression taking with transfer type on the fixture level
Impression taking with transfer type on the fixture level

Fig11.
G-mask state, trimming was done for gingival forming
G-mask state, trimming was done for gingival forming

Fig12.
G-mask state, trimming was done for gingival forming
G-mask state, trimming was done for gingival forming

Fig13.
Abutment try-in
Abutment try-in

Fig14.
Resin cap try-in
Resin cap try-in

Fig15.
Final prosthesis
Final prosthesis

Fig16.
The pictures taken after the final prosthesis on the Rt Molar
The pictures taken after the final prosthesis on the Rt Molar

Fig17.
The pictures taken after the final prosthesis on the LT 2nd molarafter 5months
The pictures taken after the final prosthesis on the LT 2nd molarafter 5months

Fig18.
Final prosthesis x-rays
Final prosthesis x-rays

Fig19.
Finished panoramic x-ray
Finished panoramic x-ray
Internal Hex Fixture : SST Type

Patient Information
- Age : 59
- Gender : old male
- Implant : #14, 16: GBR ¡æ SST implants placement
#46 : SST implants placement
#26, 27 : sinus graft + simulaneous SST implants placement
#36: immediate SST implants placement + GBR

Fig1.
#14, 15 teeth extraction and sinus grafting performed
#14, 15 teeth extraction and sinus grafting performed

Fig2.
Tension free suture was done through undermining after GBR.
Tension free suture was done through undermining after GBR.

Fig3.
5 months later the GBR
5 months later the GBR

Fig4.
Using the guide-pins for path & position of the implants
Using the guide-pins for path & position of the implants

Fig5.
Drillings were bone
Drillings were bone

Fig6.
SG Implants wer installed
SG Implants wer installed

Fig7.
The picture taken after the SST implant placed
The picture taken after the SST implant placed

Fig8.
Healing aboutment were inserted
Healing aboutment were inserted

Fig9.
Palacci flap was done for soft tissue management
Palacci flap was done for soft tissue management

Fig10.
The picture taken after the prosthesis treatment completed after 3months later dental implant placement 2nd molar will be extracted
The picture taken after the prosthesis treatment completed after 3months later dental implant placement 2nd molar will be extracted

Fig11.
Mandible right molar area was scheduled for implant
Mandible right molar area was scheduled for implant

Fig12.
There was a sufficient bony volume
There was a sufficient bony volume

Fig13.
Torque Wrench
Torque Wrench

Fig14.
1-stage implant was performed because of good primary stability
1-stage implant was performed because of good primary stability

Fig15.
The pictures taken after the prosthesis treatment completed after 3months implant placement
The pictures taken after the prosthesis treatment completed after 3months implant placement

Fig16.
Panoramic picture taken after the prosthesis treatment
Panoramic picture taken after the prosthesis treatment
Internal Octa Fixture : IT Type

Way to place Dental Fixture without incision of the gums
- Reduce bleeding, pain, and swelling to a minimum.
- Reduced number of complaints due to shorter treatment period and recovery period
- Reduce bleeding, pain, and swelling to a minimum.
- Reduced number of complaints due to shorter treatment period and recovery period
Patient Information
- Age : 43
- Gender : Female
- Implant : 16 ,17, 36
- Model : IT Type