Patient Information
  • Age : 61
  • Gender : old male
  • Implant : 15, 16, 17, 27 SST implants
Fig1.
Implant placement combined socket lifting
Fig2.
Initial panorama x-ray
Fig3.
Sinus grafting performed by crestal approach on the #16,17 area
Fig4.
SG Implants were installed. Pictures of SST system #15,16 SFSR4111 . #17 SFSW511
Fig5.
Primary stability checked with Torque Wrench
Fig6.
The picture taken after the SST implants placed
Fig7.
Healing aboutments were inserted
Fig8. #14, 15, 16 SST implants installed & Healing aboutments were insertered. #27 implant was inserted combined socket lifting
Fig9.
Healing sequences of sinus area
Fig10.
Impression taking with transfer type on the fixture level
Fig11.
G-mask state, trimming was done for gingival forming
Fig12.
G-mask state, trimming was done for gingival forming
Fig13.
Abutment try-in
Fig14.
Resin cap try-in
Fig15.
Final prosthesis
Fig16.
The pictures taken after the final prosthesis on the Rt Molar
Fig17.
The pictures taken after the final prosthesis on the LT 2nd molarafter 5months
Fig18.
Final prosthesis x-rays
Fig19.
Finished panoramic x-ray
Internal Hex Fixture : SST Type
Patient Information
  • Age : 59
  • Gender : old male
  • Implant : #14, 16: GBR ¡æ SST implants placement
    #46 : SST implants placement
    #26, 27 : sinus graft + simulaneous SST implants placement
    #36: immediate SST implants placement + GBR
Fig1.
#14, 15 teeth extraction and sinus grafting performed
Fig2.
Tension free suture was done through undermining after GBR.
Fig3.
5 months later the GBR
Fig4.
Using the guide-pins for path & position of the implants
Fig5.
Drillings were bone
Fig6.
SG Implants wer installed
Fig7.
The picture taken after the SST implant placed
Fig8.
Healing aboutment were inserted
Fig9.
Palacci flap was done for soft tissue management
Fig10.
The picture taken after the prosthesis treatment completed after 3months later dental implant placement 2nd molar will be extracted
Fig11.
Mandible right molar area was scheduled for implant
Fig12.
There was a sufficient bony volume
Fig13.
Torque Wrench
Fig14.
1-stage implant was performed because of good primary stability
Fig15.
The pictures taken after the prosthesis treatment completed after 3months implant placement
Fig16.
Panoramic picture taken after the prosthesis treatment
Internal Octa Fixture : IT Type
Way to place Dental Fixture without incision of the gums
- Reduce bleeding, pain, and swelling to a minimum.
- Reduced number of complaints due to shorter treatment period and recovery period
Patient Information
  • Age : 43
  • Gender : Female
  • Implant : 16 ,17, 36